Article number 0232200604
| Article number | 0232200604 |
| Brand | EMH Metering |
| Order quantity per | 1 |
| Packing unit | 1 |
| Output channels | 2 |
| Phase | 3 |
| Recyclable | Yes |
| Energy supply | 3-phase from measuring voltage |
| Type of kWh meter | DIZ-meter |
| Energy registers | 2 tariff registers (T1/T2) |
| Data preservation | Voltage free in ROM memory, at least 20 years |
| Version of kWh meter | Direct connected |
| Mounting method | DIN rail |
| Safety characteristics: overvoltage category | OVC III as per EN 62052-31 |
| Safety characteristics: rated peak withstand voltage | 4 kV as per EN 62052-31 |
| Memory | 12000 entries for 1 channel |
| Load profile: recording type | Energy registers |
| Real time clock: synchronisation | Data interface |
| Real time clock: synchronisation | Mains-derived |
| Communication module: interface module | RS485 Modbus |
| MID approved | Yes |
| CE marking | Yes |
| Accuracy class reactive energy | CI. 2 according to EN 62053-23 |
| Accuracy class active energy | CI. A according to EN 50470-1, -3 |
| Height | 89.5 mm |
| Width | 107.5 mm |
| Length | 64 mm |
| Installation width | 89.5 mm |
| Installation height | 107.5 mm |
| Product weight | 0.45 kg |
| AC/DC | AC (alternating current) |
| Protection class | IP30 |
| EMC characteristics: insulation strength | 4 kV AC, 50 Hz, 1 min |
| EMC characteristics: surge voltage | ISO: 6 kV, pulse 1.2/50 µs, 500 Ω |
| EMC characteristics: surge voltage | EMC: 4 kV, pulse 1.2/50 µs, 2 Ω |
| EMC characteristics: resistance to hf fields | 10 V/m (under load) |
| Power consumption per phase: voltage circuit | <2.0 VA/<1.0 W |
| Energy consumption per phase: current path | <2.5 VA |
| Frequency | 50 Hz |
| Input channels | 1 |
| Load profile: registration period | 10 minutes |
| Load profile: registration period | 60 minutes |
| Load profile: registration period | 5 minutes |
| Load profile: registration period | 30 minutes |
| Load profile: registration period | 15 minutes |
| Maximum operating temperature | 55 °C |
| Maximum temperature storage | 70 °C |
| Minimum operating temperature | -25 °C |
| Minimum temperature storage | -40 °C |
| Optocoupler MOSFET | Max. 250 V AC/DC, 100 mA, for pulse transfer |
| Pulse values LED | 1 000...2 000 pulse/kWh (type-specific) |
| Real time clock: power reserve | Max 10 days (Gold cap) |
| Real time clock: running accuracy | Within ± 5 ppm (at 23 °C) |
| S0 output | Max. 27 V DC, 27 mA (passive) |
| Current | 0.25-5 (80) A |
| Measuring types active energy | +A, -A |
| Voltage (range) | 3x230/400V |