The MacBAT 5 corrector offers PTZ, PT, or T type corrections. The device is powered by an internal battery with the option of external power connection. MacBAT 5 converts gas volume measured by a rotary, turbine, or ultrasonic gas meter to base conditions. The gas compressibility factor is calculated using algorithms: SGERG-88, SGERG-mod-H2, AGA92-DC, AGA8-G1, AGA8-G2, AGA NX-19-mod, or a constant value of the compressibility factor K1.
MacBAT 5 is an intrinsically safe device that can be installed in Zone 0 explosive hazard areas.
Features:
- the built-in 4G LTE modem provides the ability for remote data reading
- prevents discrepancies in gas meter readings and the corrector
- detects and compensates reverse flows
- conducts measurements every second
- supports the most popular digital communication standards
- certified algorithms for natural gas, hydrogen blends, and biomethane
- operates up to 14 years without battery replacement
- large memory capacity, up to 10 years of measurement data
- offers intuitive operation and configuration via NFC with a phone
Functionalities:
- designed for turbine, rotary, or ultrasonic gas meters via LF, HF, Encoder, Wiegand (optional)
- supports NAMUR and SCR encoders in the battery mode operation
- MID certified for measuring the volume of a gas mixture containing up to 30% hydrogen (H2)
- advanced solutions preventing differences in gas meter and corrector measurements, detecting gas meter backflow
- measurement of volume increment every second from the HF input, also available during battery-powered operation
- four independent serial transmission ports (2x RS485/ RS232, Optical 62056-21, NFC IEC 14443)
- built-in 4G LTE Cat.1 and 2G modem (optional)
- up to 8 intrinsically safe configurable binary inputs, including two NAMUR inputs for inductive sensors, functioning even during battery mode operation
- intrinsically safe digital and frequency outputs
- internal or external pressure sensors
- built-in gas meter load profile analysis function
- support for biogas measurement
- integration with a Building Management System (BMS) via MODBUS RTU, Modbus TCP, or pulse-driven communication with Vb and Vm counters
- capability of reading/controlling in Modbus MASTERmode for up to 16 external devices, using Modbus RTU protocol via RS485 (e.g., digital pressure transducers, EM series expansion modules)
- capability to control gas odorizers (using a frequency/ current loop converter or EM-1 expansion module)
- direct collaboration with gas chromatograph